Heat pumps · UK · Guide

Air source heat pumps: a UK buyer’s guide

For most British homes with radiators, the answer is an air-to-water heat pump. Here is how to choose among air source heat pumps, size yours properly and get the government grant off the price.

Heat pump running cost calculator

Dark grey air source heat pump outdoor unit on a paved base by a wooden fence, with pot plants around it
An air source heat pump in a garden. Photo: Octopus Energy · Press photo · octopus.energy

Key facts

  • The Boiler Upgrade Scheme takes £7,500 off an air-to-water heat pump and £2,500 off an air-to-air one, in homes in England and Wales.1
  • Off-gas homes replacing oil or LPG get £9,000 until 31 March 2027.23
  • Installed heat pumps are zero rated for VAT until 31 March 2027, then reduced rated.4
  • Running the same heat pump at a 65°C design flow instead of 50°C cuts its seasonal efficiency from 3.4 to 2.8.5
On this page
  1. Air-to-water or air-to-air: which do you need?
  2. How big a heat pump does your home need?
  3. What an air source heat pump system includes
  4. Radiators, pipes and the hot water cylinder
  5. How loud is an air source heat pump?
  6. Air source heat pump models compared
  7. Grants and VAT for an air source heat pump in the UK
  8. Telling the network operator
  9. Choosing an installer
  10. Our verdict

For most British houses with radiators, an air-to-water heat pump is the one to fit: it heats the radiators and the hot water cylinder, and in England and Wales the Boiler Upgrade Scheme takes £7,500 off the price.1 If you live off the gas grid and are replacing oil or LPG, that rises to £9,000 until 31 March 2027.23 Installed heat pumps are also zero rated for VAT until the same date.4

The box on the outside wall is the easy part. The decisions that matter are which kind of air source heat pump, what size, and whether your radiators and pipes are up to it.

Our verdict: on oil or LPG, get quotes this winter, because both deadlines land on the same day. On mains gas there is no rush, so spend the time on a proper heat loss survey and an installer who designs for a low flow temperature. That one choice decides more of your running cost than the brand on the box.

Air-to-water or air-to-air: which do you need?

Search for an air source heat pump and you get both kinds mixed together. They do different jobs.

An air-to-water heat pump, the standard air source heat pump, pulls heat from outside air and puts it into water. That water runs through your radiators or underfloor pipes and heats a hot water cylinder. It replaces a boiler outright, and the grant is £7,500.3

An air-to-air heat pump blows warm air into rooms through indoor units, much like an air conditioner run in reverse. It does not make hot water, so you keep an immersion heater or another way of heating it. Since the 2026/27 scheme year it has its own grant of £2,500, for homes only.1

The money follows the job. The Warm Homes Loan scheme lends up to £20,000 for an air-to-water system, before the grant comes off, but it can’t finance air-to-air yet, because MCS has no standard to certify those installations against.6 If you want one system that heats the whole house and the taps, air-to-water is the answer. Air-to-air makes sense where you mainly want a few rooms warm and are happy to keep heating water another way.

How big a heat pump does your home need?

Size comes from your home’s heat loss: how many kilowatts of heat escape on a cold day. A good installer measures it room by room. Octopus does this on its free survey before choosing a model, and the bands it uses show how the numbers work.5

Model Typical home Heat loss it covers
Octopus Cosy 6 1 to 4 bedrooms under 5.6 kW5
Octopus Cosy 9 3 to 5 bedrooms up to 8.7 kW5
Octopus Cosy 12 larger or older homes up to 11.2 kW5

The industry rulebook is MCS’s heat pump installation standard, MIS 3005-I:2025, and MCS also publishes its own heat load calculator.7 An installer who quotes a size from the number of bedrooms alone, with no heat loss figures, has skipped the step that matters. Too small and the house stays cold on frosty mornings; too large and you pay for capacity you never use.

What an air source heat pump system includes

An air source heat pump system is more than the fan unit outside. Expect four parts: the outdoor unit, a hot water cylinder, controls, and the radiators or underfloor loops that carry the heat round the house.

The outdoor unit needs a patch of wall or ground with air around it. A Cosy is 855mm wide and 595mm deep, and stands 1,125mm tall for the Cosy 6 or 1,375mm for the Cosy 9 and 12.5 Measure the side return or the space under the kitchen window before you settle on a model.

Inside, the cylinder needs a cupboard. Hot water is the part people worry about, and the numbers are reassuring: a Cosy 9 reheats a 180-litre cylinder from 10°C to 48°C in about 45 minutes, and a 300-litre one in about 80.5 The smaller Cosy 6 takes about 70 minutes for 180 litres, which still suits a household that showers in the morning and lets the cylinder recover through the day.5

Radiators, pipes and the hot water cylinder

A heat pump runs most efficiently at a lower water temperature than a boiler, which is why the quote often includes work inside the house. A typical installation quote can cover improvements to radiators, pipework and water tanks.6 Octopus fits a new high-efficiency hot water cylinder if you don’t have one, works with copper or plastic microbore pipe of 10mm or larger, and offers a high-temperature option for homes that need it.5

Flow temperature is where the running cost hides. The Cosy 6 has a seasonal efficiency (SCOP) of 3.4 when the system is designed for 50°C water, and 2.8 when it is designed for 65°C.5 At the capped electricity price for October to December 2026, each kWh of heat costs noticeably less at a 50°C flow temperature than at 65°C.85 Bigger radiators that let the system run cooler pay you back every winter. Put your own figures into our heat pump running cost calculator.

How loud is an air source heat pump?

Compare models on sound power, the figure measured at the unit itself. It is the only noise number that is like-for-like across brands.

The quietest Cosy is not the smallest: the Cosy 9 is rated at 56 dB(A) at a 55°C flow, against 58 dB(A) for the Cosy 6 and 61 dB(A) for the Cosy 12.5 The Vaillant aroTHERM plus starts at 54 dB(A), and every size except the 10 kW model carries Quiet Mark approval.9

Placement still matters as much as the rating. Ask the installer to mark the spot on a plan before you sign, and think about bedroom windows, yours and your neighbours’.

Air source heat pump models compared

Octopus’s own Cosy range and Vaillant’s aroTHERM plus are a good pair to weigh up, and you can see every number for both. Both use R290, a natural refrigerant with a 100-year global warming potential of 0.02.59

Model Heat output Sound power Hot water and flow Warranty
Octopus Cosy 6 5.6 kW at −5°C, 50°C flow 58 dB(A) 70°C max flow 8 years5
Octopus Cosy 9 8.7 kW at −5°C, 50°C flow 56 dB(A) 70°C max flow 8 years5
Octopus Cosy 12 11.2 kW at −5°C, 50°C flow 61 dB(A) 70°C max flow 8 years5
Vaillant aroTHERM plus 3.5, 5, 7, 10 or 12 kW from 54 dB(A) up to 25% more usable hot water at 75°C flow 2 years, extendable to 79

Vaillant’s longer warranty comes only through its Platinum and Renewable Partner installers, who also register the unit with a Vaillant cylinder.9 The aroTHERM plus also has the wider spread of sizes, which helps a small flat or a large farmhouse. Octopus quotes a typical installed price for the Cosy; Vaillant leaves the price to the installer.

Grants and VAT for an air source heat pump in the UK

In England and Wales the Boiler Upgrade Scheme pays £7,500 towards an air-to-water system, £2,500 towards air-to-air, and £9,000 towards air-to-water for off-gas homes that replace oil or LPG.123 The installer applies and the grant comes straight off your quote, so you never handle the money. The scheme itself has been extended to 2030, so the £7,500 grant is not the deadline; the oil and LPG uplift is.1

Three rules catch people out. You get one grant per property; there is no grant for a hybrid system that keeps a fossil-fuel boiler alongside the heat pump; and you cannot claim to replace an existing low-carbon system.3

VAT on installed heat pumps is zero rated until 31 March 2027 and reduced rated from 1 April 2027.4 Scotland is outside the Boiler Upgrade Scheme and has its own grant and interest-free loan; our heat pump grant explainer covers both, and what an air source heat pump costs puts the numbers together.

Telling the network operator

A heat pump adds a large electrical load, so the local network operator needs to know about it. In SSEN’s area, where the existing supply is suitable your installer fits the heat pump and notifies SSEN within 28 days.10

If nobody is sure of the rating of the cut-out, the sealed box where the supply enters, or whether the cable is shared with a neighbour (“looped”), the installer applies for a Load Check before work starts, and SSEN typically replies within 10 working days.10 Ask your installer early whether your home needs one, because a supply upgrade sets its own timetable.

Choosing an installer

For the grant, your installer must be MCS certified for heat pumps and belong to an approved consumer code, a set of consumer-protection standards the business signs up to.1 MCS’s search tool lets you filter for installers registered for the Boiler Upgrade Scheme.11

Once the installer applies, Ofgem issues a voucher that lasts three months for an air source heat pump, and you confirm that the application was made on your behalf. Ofgem may also contact you directly to check your identity.1 Two contract details matter. The grant must appear as an upfront discount on your quote, and you must end up as the legal owner of the heat pump, so hire purchase, conditional sale and consumer hire deals rule the grant out.1 A payment plan in instalments can still qualify.

Ask every installer for the same three things in writing: the room-by-room heat loss figure, the design flow temperature, and the expected SCOP at that temperature. Quotes that can’t give you all three are hard to compare and harder to hold to account.

Our verdict

  • Off the gas grid on oil or LPG: act now. The extra £1,500 for oil and LPG homes and the zero VAT rate both end with March 2027, so get two or three quotes with heat loss figures before Christmas.34
  • On mains gas with radiators: an air-to-water heat pump designed for 50°C or lower. Pay for bigger radiators where the survey says so; the efficiency gain repays you every year.5
  • Heating a few rooms, happy with an immersion for hot water: air-to-air, with its £2,500 grant.1
  • Want a hybrid with your gas boiler kept as back-up: you lose the grant entirely, so price it honestly against a full heat pump.3

Grant amounts and dates change. We log every change on our rule-changes page, and the wider choice between air source, ground source and air-to-air is in our heat pump guide.

Products compared

Show all 3 ▸
ProductHeat outputEfficiencyNoiseSizePrice
Octopus EnergyOctopus Cosy 6
5.6 kW (−5 °C outside, 50 °C flow)1SCOP 3.4 (designed at 50 °C)158 dB(A) sound power (at 55 °C)1855 × 1,125 × 595 mm1 No published priceOctopus Cosy 6: octopus.energy
Octopus EnergyOctopus Cosy 12
11.2 kW (−5 °C outside, 50 °C flow)1SCOP 3.9 (designed at 50 °C)161 dB(A) sound power (at 55 °C)1855 × 1,375 × 595 mm1 No published priceOctopus Cosy 12: octopus.energy
Vaillant aroTHERM plus
––Sound power as low as 54 dB(A); Quiet Mark (not the 10 kW model)2– No published priceVaillant aroTHERM plus: vaillant.co.uk
All data
ProductHeat outputEfficiencyNoiseFlow temperatureRefrigerantSizeWarrantySizesEnergy class
Octopus Cosy 65.6 kW (−5 °C outside, 50 °C flow)1SCOP 3.4 (designed at 50 °C)158 dB(A) sound power (at 55 °C)170 °C max flow1R290 (natural refrigerant)1855 × 1,125 × 595 mm18 years1––
Octopus Cosy 1211.2 kW (−5 °C outside, 50 °C flow)1SCOP 3.9 (designed at 50 °C)161 dB(A) sound power (at 55 °C)170 °C max flow1R290 (natural refrigerant)1855 × 1,375 × 595 mm18 years1––
Vaillant aroTHERM plus––Sound power as low as 54 dB(A); Quiet Mark (not the 10 kW model)2–R2902–2 years, extendable to 7 through approved installers23.5, 5, 7, 10 and 12 kW2A+++2
  1. octopus.energy
  2. vaillant.co.uk

Specifications come from each maker's own product page or datasheet, taken on 14 NOV 2026. Our picks are editorial judgement from those published specs, not test results; we haven't tested the products. – means the maker publishes no price.

Calculators

Heat pump running cost calculator

A heat pump's yearly electricity cost compared with your current heating, and the price after any grant.

Pre-filled from: Ofgem, Department for Energy Security and Net Zero

Open the calculator

Example figures · Difference a year · as of 18 November 2026 SCOP 3.4 −£76 … +£266 a year

Rules and grants in force

Boiler Upgrade Scheme

Ofgem

£7,500 as of

A grant towards replacing a fossil-fuel boiler: £7,500 for an air source or ground source heat pump, £5,000 for a biomass boiler and, since the 2026/27 scheme year, £2,500 for an air-to-air heat pump (homes only). An EPC is no longer needed. The installer applies for the grant.

Official source ofgem.gov.uk

Updated · against ofgem.gov.uk

Boiler Upgrade Scheme: £9,000 for homes replacing oil or LPG

Ofgem

£9,000 as of

Homes off the gas grid in England and Wales that replace oil or LPG heating can get £9,000 towards a heat pump. The higher amount started on 21 July 2026 and runs until 31 March 2027.

Next change 31 MAR 2027 · in 133 days — £9,000 heat pump grant for oil and LPG homes ends · ofgem.gov.uk

Official source ofgem.gov.uk · gov.uk · gov.uk

Updated · against ofgem.gov.uk

Temporary zero rate of VAT on installed heat pumps, solar panels and batteries

HM Revenue & Customs

0% as of

Installed energy-saving materials, including heat pumps, solar panels and batteries, have a temporary zero rate of VAT until 31 March 2027, after which the reduced rate applies.

Next change 01 APR 2027 · in 134 days — VAT on installed heat pumps, solar panels and batteries rises to 5% · gov.uk

Official source gov.uk

Updated · against gov.uk

Dated rule changes

  1. in 133 days

    £9,000 heat pump grant for oil and LPG homes ends

    The higher Boiler Upgrade Scheme amount for off-gas homes in England and Wales replacing oil or LPG runs until 31 March 2027.

    ofgem.gov.uk · Updated

  2. in 134 days

    VAT on installed heat pumps, solar panels and batteries rises to 5%

    The 0% rate on installed energy-saving materials ends on 31 March 2027; from 1 April 2027 they carry the reduced rate of 5%.

    gov.uk · Updated